Number of slots; from 25 to 400
Number of drives; from 1 to 24
Supported drive types;Half-Height(HH) LTO Drives
Total system capacity
LTO-9 (standard / compressed); 450 to 7,200 / 1,125 to 18,000
LTO-8 (standard / compressed); 300 to 4,800 / 750 to 12,000
LTO-7 (standard / compressed); 150 to 2,400 / 375 to 6,000
Form factor
Module form factor;Rackmount (3U)
Minimum size;One module (3U)
Maximum size;Eight modules (24U)
Accommodation;Only in the rack
Scalability; Rackmountable up to 24U / incremental by 3U and 25 slots (CoD licensing)
Functional features
Inventory speed; From 1 to 6 minutes (depending on configuration)
Insertion/extraction options;Customizable: 0 to 240 slots (incremental by 5 slots)
Upgrade modules; Any module can be added in less than 30 minutes
Rack Mounting Requirements;The library must be mounted in a standard 19-inch rack with support for a depth of 36.4 inches (92.5 cm)
Conjugation
Drive interfaces; 8 Gb optical and 6/12 Gb SAS
Management interface;Dual 1 GbE
Library Interface; End-to-end Data Bridge drives, 1 GbE with remote GUI and RESTful web services for library management
Reliability and availability
MSBF;More than 2 million
MTTR;30 minutes
Напряжение;От 100 до 240 VAC, от 50 до 60 Hz
Power supply;Optional 2N/80 PLUS Gold certified power supplies
Dual robotization;No
Dimensions
Control module; 5.2in x 17.4in x 36.4in (13.2cm x 44.1cm x 92.45cm)
Expansion module; 5.2in x 17.4in x 36.4in (13.2cm x 44.1cm x 92.45cm)
Parking module;Not present
Environmental requirements
Temperature
Recommended;LTO-7, LTO-8: 16 to 25°C (61 to 77°F), LTO-9: 15 to 25°C (59 to 77°F)
Acceptable;LTO-7, LTO-8: 16 to 35 °C (61 to 95 °F), LTO-9: 15 to 35 °C (59 to 95 °F)
For delivery conditions;-23 to 49 °C (-9 to 120 °F)
Relative humidity
Recommended; 20 to 50% (non-condensing)
Permissible; from 20 to 80% (non-condensing)
For delivery conditions;5 to 80% (non-condensing)
Maximum temperature difference
Recommended;5°C/hour
Acceptable;5 °C / hour
Maximum change in humidity
Recommended;5%/hour
Acceptable; 5% / hour
Temperature limits according to humidity
Recommended: LTO-7, LTO-8: Dry bulb temperature <= 26°C (79°F), LTO-9: Max dew point 22°C (72°F)
Allowable: LTO-7, LTO-8: Dry bulb temperature <= 26°C (79°F), LTO-9: Max dew point 22°C (72°F)
For delivery conditions: Dry bulb temperature <= 26°C (79°F)
Maximum height
Permissible;3,048 m (10,000 ft)
For delivery conditions;12,192 m (40,000 ft)
Certification
Safety standards; IEC 60950-1 and IEC 62368-1, considering international differences, EN62368-1, UL 62368-1, IS3525 (Part 1), CNS14336-1
Emission standards; FCC Part 15 Class A, EN 55032 Class A, KN 32, VCCI, EN 300 386, CNS 13438 Class A, ICES-003 Class A
Immunity standards; EN 55024, KN 35, KN24
cTUVus (USA and Canada), FCC (USA), ICES (Canada), CE (Europe), UKCA (United Kingdom), GS Mark (Germany), CMIM (Morocco), VCCI (Japan), KC (South Korea), BSMI (Taiwan), BIS (India), RCM (Australia/New Zealand), EAC (Eurasian Customs Union)